On an air conditioning job, cable ties hold pipe pairs together, keep cables tidy along the run, and fix flexible duct to its collar. Each of those jobs needs a different tie. This guide covers which cable ties to use for HVAC and duct work, inside the roof and out in the sun.
Quick guide: HVAC cable ties by job
| Job | Cable tie |
|---|---|
| Pipe pair and cable along an outdoor run | 4.8mm black (22kg, UV stabilised) |
| Larger bundles, drain line with pipes | 7.6mm black (55kg), up to 750mm long |
| Flexible duct onto a collar or spigot | 9mm black (80kg), 530mm to 1220mm long |
| Near hot surfaces or in a coastal spot | Stainless steel cable ties (316 for salt air) |
| Fixing a run to a wall or frame | Cable tie mounts or mountable cable ties |
Outdoor pipe and cable runs
The run from the outdoor unit to the wall often sits in full sun for years. Use black nylon cable ties there. Ours are UV stabilised. White and colour ties are best kept indoors.
- Space ties evenly along the run, so the pipes and cable do not sag between them.
- Pull the tie firm, but not so tight that it digs into the pipe insulation. A crushed spot in the lagging can let condensation form on the pipe.
- Cut tails flush so nothing sharp sticks out. A cable tie gun tensions and cuts in one action.
Flexible duct to collars
Flexible duct is usually fixed to a round collar or spigot with a long, wide tie pulled tight around the outside. The tie needs to be long enough to go around the full duct with room to feed into the head. Measure around the duct, add about 50mm, and pick the next length up.
For most domestic duct sizes, a 9mm black cable tie gives you both the length and the strength. Always follow the duct maker's fitting instructions, including any tape or sealing layer they ask for under the tie.
Inside the roof space
Roof spaces get very hot in summer. Nylon has a temperature limit, so check it before you fix ties close to hot plant, flues or metal roofing. Our cable tie temperature rating guide explains what to look for. Where the heat is too high for nylon, switch to stainless steel cable ties. Use nylon coated 304 where bare steel could rub cable sheathing or insulation.
Coastal installs
Salt air is hard on metal fittings. For outdoor units near the coast, choose 316 stainless steel cable ties. For more on the two grades, see 304 vs 316 stainless steel cable ties.
Fixing the run to the building
To hold a pipe and cable run against a wall or frame, use cable tie mounts (20mm and 28mm) and thread a tie through each one. On timber or metal, a mountable cable tie screws straight on through the hole in its head.
Common questions
What size cable tie for air conditioning pipes?
For a standard pipe pair with cable, 4.8mm black ties in 300mm or 370mm suit most runs. Use 7.6mm for larger bundles.
Can I use white cable ties outside on an AC run?
It is better not to. Our white ties are not UV stabilised. Use black nylon or stainless steel outdoors.
Do you sell cable ties in bulk for installers?
Yes. Nylon cable ties come in packs of 100, and the price per pack drops at 5 and again at 10 packs. For bigger orders, call 0400 442 202 or email info@zippytieman.com.au.
Shop all our cable ties, or see the full cable tie uses by industry guide.